Water sector supply chain intelligence
Securin traced the 236 vendors behind America’s water systems and found nearly twice as many vulnerabilities as public records show, including 20 exploited flaws missing from the federal government’s list. The index is measured against CISA, FBI, EPA, and WaterISAC records of how these systems fail and how they are attacked.
R1 · Public record
376 CISA advisories name water as an affected sector since 2017. A weakness (CWE) is the flaw in how something was built; a vulnerability (CVE) is one place it shows up. Very little of what the advisories describe is ever used. What is used mostly comes from somewhere else. Data through November 20, 2026.
R2 · 2026 by quarter
The same public record, cut by quarter for 2026. The fourth quarter runs to November 20 and is shown as a part quarter; do not read its lower counts as a decline.
CISA published 23 water tagged advisories in the third quarter, the most since the second quarter of 2020. Through November 20 the 2026 total is 57, against 34 for all of 2025.
In the first quarter 4 of 71 CVEs had no vendor fix. In the second it was 14 of 30, and in the third 27 of 60. Nearly half of what was disclosed from April to September came with mitigations only.
Nine vendors appeared in a water advisory for the first time in the third quarter, against four and three in the two before. Several are small or open source: lwIP, the OPC Foundation, MZ Automation, IXON, Haiwell.
The first quarter was led by input validation, all 14 cases from one Siemens advisory with 51 CVEs. From the second quarter the leading class is missing authentication, the same weakness behind the controller attacks of the summer.
The third quarter saw more than 30 Minnesota systems hit and reports from at least 12 states. No water tagged CVE was added to the CISA exploited list that quarter. The controllers had no password set, so there was no vulnerability to list.
R3 · The stack
Twelve technology layers sit between a reservoir and a water bill. Red squares have been attacked or carry an exploited flaw. Hollow squares have no public vulnerability record at all, which is a statement about research, not about safety.
In water, with public proof of attack: an exploited flaw, a federal alert, or a documented incident.
Rockwell; Siemens; Schneider Electric; Unitronics; Sierra Wireless; Trimble Cityworks; SonicWall; Cisco; TeamViewer; SimpleHelp
In water, but nobody has measured exposure or exploitation. Flaws are published with no sign of use, or nothing is published.
Advantech; Ignition; Hach; Badger Meter; Sensus; Grundfos; Esri; Tyler Technologies; Mission Communications
Not on any purchase order: code inside a product, the controller inside a packaged skid, the integrator build copied across clients.
lwIP; GoAhead; Erlang/OTP; CODESYS runtime; protocol libraries; membrane and UV skids; integrators; contract operators
R4 · Products
Vendors are the wrong unit for patching; products are. The water tagged advisories name 637 product families. Each square below is one product, shaded by how many CVEs it carries. The other vendors in the index have no advisory, so their products are listed by name only.
Why 88 and not 236: product level detail exists only where CISA has published a water tagged advisory, and those advisories name 88 vendors. Of the 236 vendors in the index, 82 are named in a water tagged advisory. The other 154 are not: 99 have no CISA advisory at all, and 55 have advisories that carry no water tag. 39 of the 236 were added from the Securin platform, which maps their vulnerabilities to water; 43 from other public records: NSF drinking water listings, FCC radio authorizations, CERT@VDE advisories, and company annual reports. Seven names in the advisories are embedded component makers and tools that the index does not carry as separate entries.
None of these is a census of the water sector. The public figures cover only products a CISA advisory has named with the water tag. The Securin figures cover products with at least one CVE mapped to water. Equipment with no published vulnerability appears in neither. Securin platform data queried November 18, 2026.
Vendors with the most products in water tagged advisories. Darker means more CVEs on that product; a red outline marks an exploited CVE.
The chart above covers only vendors with a water tagged CISA advisory. The Securin platform ties products to water through the vulnerabilities they carry, and reaches further: 3,401 products across 115 of the 236 index vendors, counting a device and its firmware once.
The 39 vendors added from the platform account for 834 of those. Two chip makers dominate: Qualcomm with 499 modem chipsets and Intel with 218 processors and firmware lines, the parts inside gateways and industrial PCs. The other 37 vendors add 117 products, led by Belden with 36 and Pepperl+Fuchs with 14.
Siemens alone has 1,057 products on a water mapped vulnerability. No utility can track that by hand, which is the case for an inventory matched automatically against product level intelligence.
121 index vendors have no product on a water mapped CVE; they are in the index on advisory, alert, or sector evidence. Another 193 vendors on the platform, mostly general IT such as NetApp and Red Hat, are not in the index. Securin platform data, November 18, 2026.
Products that carry a CVE mapped to water. Lighter bars are vendors added to the index from the platform.
Siemens (111), Rockwell Automation (103), Schneider Electric (95), GE Vernova (60), and ABB (53) account for 422 of 637 products. 50 of the 88 vendors appear with a single product.
The median product carries a single CVE. The load sits in a few families: four Siemens SCALANCE wireless lines carry 72 CVEs each, and the ten heaviest products hold 195 of the 1,092.
Sibling products share firmware, so one flaw lands on a whole family. One 2020 Siemens CVE touches 27 products. A product count without a shared code map overstates how many separate things need fixing.
Across all CISA industrial advisories since 2017, the same CVE often appears under two vendor names. Hitachi Energy and Siemens share 91 CVEs; ABB and Siemens 49; Mitsubishi Electric and Siemens 29; ABB and Schneider Electric 15; Rockwell Automation and Schneider Electric 15.
Those overlaps are common components and licensed runtimes. A utility that buys from two of these vendors for redundancy may have bought the same flaw twice.
All CISA industrial advisories since 2017.
R5 · CWE analysis
The 1,092 CVEs in water tagged advisories map to 191 distinct CWE identifiers. Ranked by how many advisories carry them, how severe they are, and how they have moved over time, the picture is different from a raw CVE count.
CWE-121 appears in 61 advisories, more than any other weakness. CWE-89 (SQL injection) has the most CVEs, 89, but 67 of them come from a single 2025 Siemens TeleControl Server Basic advisory; it appears in only 20 advisories.
Severity tells a third story. Half of the CWE-306 (missing authentication) CVEs and six in ten of the CWE-78 (OS command injection) CVEs score 9.0 or higher. Neither needs memory corruption skill to use.
Counting CVEs rewards one noisy advisory. Counting advisories and critical share shows where a utility should expect the next serious flaw: authentication and command injection.
Bar is the number of advisories carrying the CWE. Red portion of the pill is the share of its CVEs scored critical.
From 2017 to 2021, one in four water tagged advisories carried a stack overflow (CWE-121) and one in ten a heap overflow (CWE-122). Since 2022 those shares are 5 percent and 1 percent.
Missing authentication (CWE-306) rose from 6 to 11 percent and is now the most common weakness in new advisories. OS command injection (CWE-78) more than doubled.
Memory flaws are being reported less often. What is reported now is cheaper to exploit: a function that never asks who is calling.
2017 to 2021 (217 advisories) against 2022 to 2026 (159 advisories).
Grouping CWEs into classes, memory corruption (22 percent), authentication and access control (21 percent), and injection (19 percent) are nearly level overall. By vendor layer they are not.
Cellular and network gear fails on authentication: half of its CVEs are missing or weak access control. That is the layer the 2026 campaign came through. Embedded components are two thirds memory corruption.
27 CVEs are hard coded, default, or weak credentials (CWE-798, CWE-259, CWE-1188, CWE-1392, CWE-1393, CWE-521). One of them, the Unitronics default password, is the flaw behind the 2023 controller takeovers.
Share of CVEs in CISA water tagged advisories. Layers with at least 30 CVEs.
The 17 exploited CVEs do not follow the top of the chart. Eight are improper input validation (CWE-20): seven in inherited Cisco network code and one in an embedded web server. The three native to water products are an insecure default (CWE-1188), an unrestricted file upload (CWE-434), and deserialization of untrusted data (CWE-502).
None of the 66 stack overflow CVEs is on the exploited list.
Securin sees the same pattern across its wider set of 2,015 sector CVEs: input validation leads at 262, and among the 46 exploited, input validation leads again with 17.
Following the 2,015 Securin water CVEs from disclosure to public exploit code to exploitation shows three different behaviors.
| Family | CVEs | Public code | Exploited | Code used |
|---|---|---|---|---|
| Memory corruption | 542 | 99 | 16 | 16% |
| Injection | 359 | 31 | 5 | 16% |
| Authentication and access control | 448 | 44 | 8 | 18% |
Memory corruption is where researchers publish. Nearly one in five has exploit code. Integer overflow has the highest rate among the larger memory classes, 13 of 37, and not one is known exploited: proof of concept code for a crash is common, a working attack on a controller is not.
Injection is under studied. SQL injection is the extreme: 129 CVEs, one public exploit. The flaws sit in SCADA and HMI web software that few researchers have a copy of.
Authentication and access flaws rarely get public code. One in ten has it, half the rate of memory corruption. Where code exists it is used about as often: 8 of 44, against 16 of 99 for memory corruption. Hard coded credentials stand out: three public exploits, two used. A password needs no exploit development.
Families use the same class groupings as the chart above, applied to the Securin water set. They overlap; a CVE with two weakness classes can count in two rows. Code used is exploited divided by public code.
17 CVEs in water tagged advisories that are on the CISA exploited list.
Threat models for industrial systems are usually written from expert opinion. Ozkan and Singelee showed that a ranked list per component type can instead be derived from disclosed weaknesses. Applying that method to the 2,015 vulnerabilities Securin maps to water gives one row per layer of the stack.
Controllers carry the volume and nearly all of the exploitation: 41 of the 46 exploited flaws, most of it inherited network code. SCADA and HMI software is led by SQL injection, the class with the highest Securin weakness score in the set, with memory bounds errors and path traversal behind it. Cellular and network gear is where weak cryptography and hard coded credentials concentrate; more than one in four of its flaws has public exploit code, and it holds 9 of the exploited flaws.
The model tells a utility what to ask each vendor. For a SCADA vendor: injection testing. For a modem vendor: credential handling. For a controller vendor: which third party network code is inside.
Securin water set. The number after each CWE is the Securin Risk Index for that weakness class, 0 to 10, across all software.
| Layer | CVEs | Exploit code | Exploited | Leading weaknesses | Most mapped technique |
|---|
Securin scores every weakness class from what attackers do with it across all software. Set against the water record, the scores and the exploitation do not line up, and the gaps are the finding.
SQL injection scores 9.4 and accounts for 129 water CVEs, yet one has public exploit code and none is known exploited. OS command injection scores 9.28 with 48 water CVEs and nine public exploits, none exploited yet. Input validation scores 4.69 and holds 17 of the 46 exploited flaws.
Exploitation in water so far has followed inherited code, not the weakness classes attackers prefer elsewhere. The injection classes are the unspent inventory.
SQL, command, and code injection together account for 214 water CVEs. None is known exploited and 13 have public exploit code. They are not spread evenly.
| Vendor | Injection CVEs | Share |
|---|---|---|
| Siemens | 108 | 50% |
| Advantech | 44 | 21% |
| mySCADA | 12 | 6% |
| Moxa | 7 | 3% |
| Ecava | 6 | 3% |
Two vendors hold 71 percent. Most of it arrived in two batches: 53 CVEs published in 2021 and 72 in 2025. A single round of security testing on one web product produces dozens of findings at once.
59 need no login. They are reachable over the network without credentials, and 36 of those are rated 9.0 or higher. Command injection is further along than SQL injection: 9 of its 67 CVEs have public code, against 1 of 129.
The products are SCADA and HMI web interfaces. These are the screens that vendors and integrators most often expose for remote support, which is the condition that turns a dormant injection flaw into an entry point.
Injection here means CWE-89, CWE-78, CWE-77, and CWE-94 in the Securin water set. Vendor counts use the vendor named on each CVE.
The eight largest weakness classes in the water set and four that attackers favor elsewhere, highest score first.
| CWE | Weakness | Score | CVEs | Public code | Exploited |
|---|
R6 · Analysis
Public vulnerability data and real attacks on water point in different directions. Advisories pile up on SCADA software. Attackers came in through cellular modems and controllers with no password.
On July 26 and 27, 2026, more than 30 Minnesota community water systems lost control of equipment. By early August, reports covered at least 12 states. Attackers changed passwords and IP addresses on Rockwell MicroLogix 1100 and 1400 controllers; one victim found modified logic.
CISA advisory AA26-097A describes the technique and names no CVE. The path was a reachable controller, usually behind a cellular modem that nobody had documented.
Patch status was not the deciding factor. Reachability was. MicroLogix 1400 is half of all exposed Rockwell controllers, and MicroLogix 1100 was discontinued in April 2022.
Reconstructed from the FBI and EPA alert, CISA AA26-097A, Censys, and Forescout.
CISA labels each advisory with the sectors it affects. Filtering on water returns 376 advisories. It does not return most advisories for the controllers named in the 2026 federal alerts.
The advisory for CVE-2021-22681, the Rockwell flaw added to the exploited list in March 2026, is tagged Multiple. Ignition has nine advisories since 2017 and none carry the water tag. Mitsubishi Electric has more than 130 and none do.
Matching by sector is not safe. Matching has to be by product, and that requires knowing the products.
CISA advisories since 2017 for products that run water systems.
Of the 17 exploited CVEs, only three belong to a product a water operator would recognize: Unitronics Vision, Sierra Wireless AirLink, and Trimble Cityworks.
Ten are Cisco IOS flaws inherited by Rockwell Stratix switches. Four are open source components shipped inside other products: a web server in GE MDS radios, an SSH library in Siemens SINEC OS, a database in ABB Ability Zenon, and the Linux kernel in ABB and Siemens devices.
14 of 17 are supply chain flaws in the literal sense. A vendor list without a component list misses most of the proven risk.
CVEs in water tagged CISA advisories that are also in the Known Exploited Vulnerabilities catalog.
Five vendors account for 191 of the 376 water tagged advisories. Advantech is second with 48 and has the most critical CVEs in the set, yet none of the CVEs in those advisories is on the exploited list.
Unitronics has two. At least 75 of its controllers were compromised between October 2023 and January 2024 through a default password.
Ranking vendors by CVE count measures how much research a vendor attracts. Ranking by exposure and attacker interest gives a different order.
Red marks vendors hit in a documented water campaign.
99 of 236 vendors have no CISA advisory at all. Eighteen of the 19 metering vendors in the catalog are in that group, along with most pump, analyzer, billing, and asset management vendors.
No record usually means no researcher has looked, the vendor has no disclosure program, or fixes ship silently. In 2025 ransomware actors reached utilities through a billing software provider.
We know these products are in the plant. Nobody can say what is wrong with them.
Ring shows vendors with zero CISA advisories out of all vendors in the layer.
The FBI and EPA noted that similar network setups provided by third parties may have let attackers repeat one success across many victims. CISA warned that modems installed by operators, vendors, or integrators may not be documented.
In late 2024, Censys found nearly 400 water HMIs on the open internet, all running the same browser based software; 40 required no login. A former contractor employee remotely disabled protections at the Discovery Bay, California plant.
The unit of risk is the integrator template, not the single utility. One build, copied across dozens of small systems, fails everywhere at once.
Illustration of the July 26 and 27, 2026 pattern: 30+ Minnesota systems in two days.
Water tagged advisories peaked in 2020, fell by two thirds, and have climbed every year since 2022. With six weeks left, 2026 already stands at 57.
The mix has changed. In 2026 the list includes protocol stacks and libraries (lwIP, lib60870, EtherNet/IP and OPC UA stacks) that live inside devices from many makers.
More of the new disclosures are at the component level, the layer utilities are least able to map.
2026 is through November 20.
R7 · Adversaries
Two adversaries use two halves of the supply chain. State linked actors and hacktivists go straight at controllers and HMIs. Ransomware crews come through the IT perimeter and stop the plant by encrypting the Windows servers that run it.
CISA exploited catalog entries flagged for ransomware use (362 of 1,792). Vendors in this catalog only.
Not one exploited CVE belonging to Rockwell, Siemens, Schneider Electric, Unitronics, Sierra Wireless, or Trimble is flagged for ransomware use. Every ransomware linked flaw in the water stack sits in the IT layer.
The outcome is still operational. Minot, North Dakota ran its plant by hand for about 16 hours in March 2026 after ransomware hit a SCADA server.
For ransomware, the vendors that matter are the firewall vendor, the remote support tool, and the managed service provider. 25 ransomware linked CVEs also sit inside industrial products that embed PAN-OS, FortiOS, Windows, or Log4j.
| Actor | Type | What it goes after | Record |
|---|---|---|---|
| CyberAv3ngers | Iran; IRGC affiliated | Unitronics Vision controllers on default port and password. | AA23-335A. IRGC actors 10.8 percent and CyberAv3ngers 5.4 percent of 75 water attacks Securin analyzed in 2024. |
| July 2026 campaign | Unattributed | Rockwell MicroLogix 1100 and 1400 behind cellular modems. Advisory also names Modicon M340 and S7-1200. | FBI and EPA alert; CISA AA26-097A. A persona calling itself APT Iran claimed the Minnesota attacks, per Check Point Research; unconfirmed. |
| Handala | Iran linked, per researchers | Utility IT and customer data; claimed California water breaches in June 2026. | Claims are unverified. |
| Cyber Army of Russia Reborn | Russia; tied to Sandworm | HMIs reached over exposed remote access; Muleshoe and Abernathy, Texas. | With Sandworm, 16.2 percent of 2024 water attacks in Securin analysis. |
| Z-Pentest, NoName057(16) | Russia; hacktivist | Control system manipulation at Danish water plants; denial of service. | Securin threat intelligence report, March 2026. |
| Volt Typhoon | China; state | Perimeter devices, for quiet long term access to utilities. | Repeated warnings from US officials. |
| Cityworks intruders | Chinese speaking actor | Trimble Cityworks asset management on IIS (CVE-2025-0994). | Shared by WaterISAC; on the exploited list. |
| TAT26-12 | Unknown; AI assisted | vNode SCADA interface at a Monterrey, Mexico utility. | Dragos. Password spraying failed. |
| Akira | Ransomware | SonicWall SSL VPN; Cisco ASA and FTD (CVE-2023-20269). | WaterISAC and EPA bulletin, Q1 2026. |
| Ryuk | Ransomware | 15 CVEs, 11 on the exploited list, including EternalBlue and Zerologon. | Securin report, March 2026. |
| Black Basta | Ransomware | Utility corporate IT. | 5.4 percent of 2024 water attacks in Securin analysis. |
| Qilin, Play, INC, Clop | Ransomware | Most active crews of 2025 across sectors; perimeter and file transfer flaws. | WaterISAC and EPA bulletin. No water victim named. |
R8 · Who targets water
The Securin platform holds 18 threat group records that target water and wastewater systems. Several of the 11 Iranian records are alternate names or general labels for the same actors, so the number of distinct groups is smaller. Reading their tooling against the sector vulnerability list shows where the two meet, and where they do not.
Six of the 18 groups have exploited vulnerabilities on record. Together they carry 86 distinct exploited CVEs. Only 2 of those appear among the 2,015 vulnerabilities mapped to water: the Unitronics default password and Cisco Smart Install, which reaches water through Rockwell Stratix switches. Only 15 carry any industrial sector mapping at all.
The rest sit on the products every organization runs: Microsoft, Cisco, Fortinet, Citrix, Ivanti. By product type the kit is remote management, network devices, security tools, and secure access. 43 of the 86 are also used by ransomware crews.
A water utility that patches only what a water advisory names covers 2 of the 86 flaws these groups are known to use. The other 84 are in the firewall, the VPN, and the mail server.
86 exploited CVEs held by groups that target water, by vendor. Securin platform, November 23, 2026.
Red marks the single vendor in this list that makes water control equipment.
Counting the ATT&CK techniques recorded for each group, by tactic, separates them cleanly. Volt Typhoon is weighted toward discovery and reconnaissance: learning a network and staying quiet. Salt Typhoon spreads across stealth, persistence, and credential access: long term espionage. CyberAv3ngers is the only group whose record is almost entirely industrial techniques, concentrated in the two tactics that end at the process: inhibit response function and impact.
That first row is the one that changes a pump or a dosing rate. It is also the shortest: 20 techniques, none of them novel, most of them a default credential and an exposed port.
Espionage groups invest in staying. The group that touched water controllers invested in almost nothing, because nothing more was needed.
Darker means a larger share of the techniques recorded for that group. The two columns right of the dashed line exist only in ATT&CK for ICS; impact is in both matrices.
Going the other way, from the water vulnerability list to the groups seen using each flaw, 11 of 2,015 CVEs have a named group attached. The busiest is Cisco Smart Install (CVE-2018-0171), used by seven groups from Russia and China. It is in the water record only because Rockwell ships Cisco network code inside Stratix switches.
The same pattern holds down the list: Cisco cluster management, Cisco SNMP, Cisco ASA, OpenSSL Heartbleed, jQuery. The flaws that state groups use against water equipment are overwhelmingly code the equipment maker did not write.
By weakness the picture is narrow. Improper input validation (CWE-20) is behind three of the 11, including the one seven groups share; memory bounds errors (CWE-119) behind two. Others include deserialization, hard coded credentials, and cross site scripting.
Attribution follows the component, not the brand on the cabinet. That is the argument for a component level bill of materials from every water vendor.
| Origin | Groups | Water CVEs used | Through |
|---|---|---|---|
| China | 7 | 4 | Cisco, Secure Boot, jQuery, Cityworks |
| Russia | 5 | 1 | Cisco Smart Install only |
| Iran | 3 | 3 | OpenSSL, SSH, Unitronics |
| Turkey | 1 | 3 | Cisco, three separate flaws |
| United States | 1 | 1 | Cisco IKEv1 |
Nine of the 11 are inherited code. Five are Cisco network software, the rest OpenSSL, SSH, jQuery, and Secure Boot. Only Unitronics and Trimble Cityworks are flaws in a product built for water.
Most are old. Seven were disclosed between 2014 and 2018. Smart Install was patched in 2018 and was still being used by Static Tundra in 2025. In water plants, where a switch stays in a cabinet for fifteen years, an old flaw is a current one.
Few of these groups were aiming at water. Of the 18 groups in the table, only Salt Typhoon and CyberAv3ngers are recorded as targeting the sector. The others were after telecom, government, or defense networks that run the same code. Water is exposed to their tooling whether or not it is on their list.
Three are not on the CISA exploited list: the jQuery, Secure Boot, and SSH Terrapin flaws. A utility that tracks only the public list would not know named groups have used them.
Groups and origins as recorded on the Securin platform. One entry with no recorded origin is left out of the origin table.
Each row is one CVE in the Securin water set; groups as recorded on the platform.
| CVE | CWE | What it is | Groups |
|---|
R9 · The chain
The same data, read as one path. Pick a vendor and a product to see which weaknesses it carries, which CVEs express them, and whether they combine into a takeover path.
Products
Weaknesses on this product
Toxic combination
CVEs
| CVE | CWE | CVSS | Flags |
|---|
R10 · Toxic combinations
No single item below is unusual. Each pairing is what turned a routine weakness into a plant outage, or would.
The July 2026 campaign. Exposed Rockwell hosts in the United States (Censys). Forescout found 70 percent of exposed controllers in the United States on mobile carrier networks.
Cellular and network; controllers
Exposed hosts in attacked cities ran firmware matching a 2017 flaw. MicroLogix 1100 was discontinued in April 2022; no patch is coming.
Controllers
Products where the flaws combine into a takeover path. 36 pair an authentication gap with a code execution flaw; 108 carry a single unauthenticated network code execution flaw scored 9.8 or higher. GE Vernova (21) and Schneider Electric (18) lead.
SCADA; controllers; network
SonicWall and Fortinet exploited CVEs with ransomware use. Minot ran manually for 16 hours after a SCADA server was encrypted.
IT perimeter; SCADA
SimpleHelp at a billing provider reached its utility customers. The FBI and EPA cite similar third party setups across July 2026 victims.
Remote access; integrators
Exploited CVEs in water advisories that are inherited code. Seven CVEs that an AI system is publicly credited with finding already sit inside industrial products.
Embedded components
R11 · Attack chains
Reconstructed from federal alerts and incident reports. Each step names the vendor layer it crosses and the ATT&CK technique it uses. The red dot is the outcome.
R12 · MITRE ATT&CK mapping
Securin maps each vulnerability to the ATT&CK techniques it enables. 2,004 of the 2,015 water vulnerabilities carry a mapping. Counted by tactic, they show which stage of an intrusion the sector is most exposed at.
1,186 vulnerabilities, 59 percent, enable initial access. 893 enable execution. Far fewer help an attacker move sideways (196) or take data out (8). An intruder in a water network does not need a second vulnerability to move; flat networks and shared credentials do that work.
The single most mapped technique is exploit public facing application (T1190), on 800 vulnerabilities and 19 of the 46 exploited ones. Endpoint denial of service (T1499) is mapped to fewer vulnerabilities, 491, but to 20 of the exploited ones, the most of any technique: for an operator, a controller that stops answering is the impact.
Defences that sit at the boundary, removing internet exposure and putting authentication in front of every device, cut off the majority of the mapped techniques at once.
Bar is all mapped CVEs; the red portion has public exploit code. A CVE can map to several tactics.
Of 4,855 technique mappings on water vulnerabilities, three are ATT&CK for ICS techniques. The rest are Enterprise. Vulnerability data describes how an attacker gets in and gains code execution; it says little about what happens at the process.
The incident record fills that half. The six attack chains above use 13 ICS techniques between them, and the CyberAv3ngers profile on the Securin platform lists 19. They overlap on the same short set: internet accessible device, default credentials, remote services, modify program, modify alarm settings, loss of view, loss of control.
Detection built only from CVE mappings will watch the door and miss the controller. The ICS techniques in the table are the ones to write alerts for.
Six of the groups that target water have technique records on the platform: 244 distinct techniques between them. Only 21 are shared by three or more groups. Those 21 are the efficient place to detect.
| Technique | Groups using it | Water CVEs enabling it |
|---|---|---|
| Valid Accounts T1078 | 4 | 498 |
| PowerShell T1059.001 | 4 | 3 |
| Data from Local System T1005 | 3 | 127 |
| File and Directory Discovery T1083 | 3 | 96 |
| Web Protocols T1071.001 | 3 | 95 |
| Exploit Public Facing Application T1190 | 2 | 800 |
| Web Shell T1505.003 | 2 | 63 |
Valid accounts is the overlap. It is the only technique used by four groups and also enabled by hundreds of water vulnerabilities: default passwords, hard coded credentials, missing authentication. Logging and alerting on account use in the control network covers more of this threat than any single patch.
Most group behavior needs no vulnerability. Only 64 of the 244 techniques are enabled by any water CVE. The shared core is discovery commands, PowerShell, remote desktop, and proxy chains: ordinary administration tools used after entry.
Half the CVE mappings match no group. 64 of the 128 techniques mapped to water vulnerabilities are used by none of these six groups. Patch priority and detection priority are two different lists.
Techniques used in the six attack chains on this page, with the tactic each belongs to. A dot marks techniques also in the CyberAv3ngers profile.
| ID | Technique | Tactic | Chains |
|---|
R13 · What gets targeted next
A CVE is one instance of a CWE. Attackers reuse technique, so the weakness types they exploit elsewhere are the best public signal for which unexploited water CVEs they will reach for next.
Across all 1,792 entries on the CISA exploited list, the most used weaknesses are input validation (CWE-20), OS command injection (CWE-78), and out of bounds write (CWE-787). The direction matters more than the total.
Comparing the last 24 months with everything before, authentication bypass (CWE-288) is up four times, server side request forgery 2.8 times, improper authentication (CWE-287) 2.5 times, and missing authentication (CWE-306) 2.2 times. Memory bounds errors and input validation have fallen to a third or less.
Inside industrial products the picture sharpens. About 1 percent of CVEs in CISA industrial advisories are ever exploited. For code injection (CWE-94) the rate is 7.2 times that, for deserialization 4.3 times, for OS command injection 3.6 times.
Water advisories hold 28 unexploited OS command injection CVEs, 33 missing authentication, 14 improper authentication, and 35 path traversal. Those are the classes to watch.
Right is rising among exploited CVEs. Up is exploited more often in industrial products than average. Circle size is the number of unexploited water CVEs.
Applying three public tests to every product: it carries an unexploited CVE; the CVE is in a weakness class attackers favor; and it is reachable over the network with no login and no user action. 122 of 637 products pass, on 96 CVEs.
A screen built from public data has a limit. The public exploited list is mostly office and data center software, so anything trained on it learns what gets attacked there. Fewer than 20 water tagged CVEs are on it. The next block replaces that label set with one drawn only from industrial products.
The screen says where to look. It does not rank. Ranking needs exploitation evidence from industrial systems themselves.
| Layer | Products | Share |
|---|---|---|
| Controllers | 55 | 45% |
| SCADA, HMI, historian | 39 | 32% |
| Cellular, radio, network | 11 | 9% |
| All other layers | 17 | 14% |
Three vendors hold nearly half. The 122 products come from 42 vendors, but GE Vernova (23), Siemens (18), and Rockwell Automation (16) account for 57 of them.
One flaw is usually enough. 101 products pass on a single qualifying CVE, and 82 have one rated 9.0 or higher. The weakness behind it is most often missing authentication (31 products), path traversal (26), or unrestricted file upload (25).
Over a third cannot be patched. 44 products have a qualifying CVE with no vendor fix, only mitigations. Thirty of those are rated 9.8 or above, among them mySCADA myPRO, SenseLive X3050, five Advantech products, seven Weintek HMI models, and four Moxa switches.
Most have gone quiet. 74 products last appeared in an advisory in 2021 or earlier. Nobody has published on them since, and the flaws are still open in the field.
Six already have a history. Six Siemens SCALANCE and RUGGEDCOM switch families pass the screen and also carry a different CVE that is on the exploited list.
Ranked by number of qualifying CVEs, then severity. Unexploited as of November 23, 2026.
| Product | CVEs | Max | CWE |
|---|
Securin maps 11,967 vulnerabilities to industrial sectors and records 193 of them as exploited in the wild, each with a date. That is enough to train on industrial products alone and to test honestly: pick a date, train on what was known then, and see which still unexploited flaws were attacked afterward.
Across six cut dates from 2020 to 2025 the model scored between 0.75 and 0.88 on a scale where 0.5 is a coin flip. CVSS scored 0.50 to 0.64 on the same flaws. Summed over the six tests, the model placed 42 of 73 later exploited flaws in its top tenth; CVSS placed five.
Nearly all of that comes from one input: whether exploit code was already public on the cut date. Weakness class and CVSS vector alone scored 0.48 to 0.69. Each test has only 7 to 18 later exploited flaws, so the ranges are wide, and the direction is the reliable part.
For industrial products, the question that predicts exploitation is not how severe a flaw is. It is whether someone has already published a way to use it.
Area under the curve at six cut dates. Higher is better; 0.5 is chance. Labels and exploit dates from the Securin platform.
Of the 2,015 water vulnerabilities, 1,969 have no recorded exploitation. 214 of those have public exploit code. Scoring them with the industrial model gives the list alongside.
Three patterns stand out. Command injection in SCADA and gateway products leads: InSAT MasterSCADA, mySCADA, Sierra Wireless. Shared components recur: OpenSSL, pppd, BusyBox, each inside several water vendors at once. And the pattern has already held once: a sibling of the two Sierra Wireless AirLink flaws shown here, from the same family, was added to the CISA exploited list in December 2025.
This is the short list a utility can act on this quarter: find these products, confirm the version, and patch or isolate before the exploit code finds them.
| Industrial CVEs, all sectors | Count | Exploited | Rate |
|---|---|---|---|
| With public exploit code | 1,174 | 193 | 16% |
| Without public exploit code | 10,793 | 0 | 0% |
No exploit code, no exploitation. Securin records no industrial vulnerability as exploited without public exploit code. In water the rate is the same: 46 of 260 with code, 18 percent, and none of the other 1,755.
When it happens, it happens fast. In 126 of 180 dated industrial cases, exploitation was recorded within 30 days of the exploit code date. In 25 it came more than a year later. The window after code appears is short, with a long tail.
Most of the 214 are old code that was never used. For 166 of them the exploit code is more than five years old. 118 are reachable over the network with no login, and 86 have an EPSS of 10 percent or more.
Risk Index and the watchlist answer different questions. Risk Index rates only two of the 214 high, because it weighs evidence that an attack has happened. The watchlist ranks what has the ingredients and has not been used yet. One is for the queue for today; the other is for the plan for next quarter.
Exploit code and exploitation dates as recorded on the Securin platform, November 23, 2026.
Unexploited, public exploit code exists, ranked by the industrial model. Risk Index and EPSS shown for comparison.
| CWE | CVE | Where it sits | Risk Index | EPSS |
|---|
R14 · Securin intelligence
How a report defines the water sector decides what it finds. The public sector tag undercounts. A naive product match overcounts. Securin maps products to the sector and tracks what attackers do with each flaw. Figures below are live from the Securin platform on November 23, 2026.
Every one of the 1,092 publicly tagged CVEs is in the Securin set, plus 923 more. 445 sit in advisories from the same years that carry no water tag. 478 come from earlier advisories and other sources. Among the 923: 126 with public exploit code, 17 exploited in the wild, 9 on the CISA exploited list. The wider set also spans 300 weakness classes against 191; 65 of them appear only in the CVEs the tag misses.
Securin records 46 water vulnerabilities exploited in the wild. The CISA list has 26 of them. The other 20 include six of the URGENT/11 flaws in the VxWorks network stack, the Schneider Modicon Modbus authentication bypass, and the 2025 Revolution Pi authentication bypass. Those 20 spread across 36 weakness classes, led by improper input validation (CWE-20).
On the 26 flaws both lists carry, Securin recorded exploitation first on 18 and the same day on 8. Among those exploited since 2023, Securin was ahead on four of seven, by 6 to 47 days, including Trimble Cityworks and the Unitronics default password.
The 46 exploited water vulnerabilities trace back to 53 weakness classes out of the 300 in the set. Two account for 25 of the 46: improper input validation (CWE-20) with 17 and memory bounds errors (CWE-119) with 8.
The Securin score for the weakness and the exploitation record do not agree, and that is useful. Input validation scores 4.69 and leads exploitation. Unchecked buffer copy (CWE-120) scores 8.39 and has three. SQL injection scores 9.4 and has none.
The weaponized set is wider: 260 CVEs with public exploit code come from 131 weakness classes, so 78 classes have working exploit code and no recorded exploitation yet.
A CVE list grows every week. The list of weaknesses behind it barely moves. Asking a vendor which weakness classes it has removed from a product is a better question than asking which CVEs it has patched.
CVEs exploited in the wild per CWE, with the Securin weakness Risk Index. A CVE can carry more than one CWE.
| CWE | Weakness | Exploited CVEs | Risk Index |
|---|
CVSS rates 427 of the 2,015 water vulnerabilities 9.0 or higher, across 127 weakness classes. Only 16 of those are among the 46 exploited. A team that patches CVSS critical first works through 411 flaws nobody has attacked and still misses 30 that somebody has.
The Securin Risk Index rates 55 high or critical, across 54 weakness classes. 38 of them are exploited: more than two in three. It combines exploit code, exploitation, ransomware and threat group use, trending discussion, weakness class, and ATT&CK tactic into one score.
The comparison has a built in advantage that should be stated: Risk Index sees exploitation as it happens, and CVSS never does. That is the point of it. For forecasting before exploitation, see the industrial model above.
Same sector, same day: a queue of 55 in place of a queue of 427, holding more than twice as many of the flaws that matter.
Bar length is how many of the 2,015 water CVEs each rule flags. Red is how many of the 46 exploited CVEs fall inside.
R15 · Patching and disclosure
460 of 1,092 water tagged CVEs list mitigations only: segment, restrict, monitor. Advantech (65), Rockwell Automation (57), and Moxa (55) account for the most. For these the utility carries the risk for the life of the device.
122 CVEs in CISA industrial advisories are on the exploited list. 54 were already listed when the advisory appeared. For the other 68 the median wait was 578 days; 29 took more than three years, and only 11 were listed within a month.
Of 376 water tagged advisories, 93 credit the vendor, 66 the Zero Day Initiative, and 22 Claroty; 59 credit no organization. Products get advisories when someone is paid to look. Meters, analyzers, and pumps mostly have no one looking.
R16 · Other public records
Six public records outside the vulnerability feeds, read against the index: security certification, internet exposure, radio authorizations, drinking water listings, German advisories, and annual reports.
ISASecure lists 109 products from 36 vendors certified against the IEC 62443 security standard. Nine vendors in this index appear on it. Most of what they certified is large process control: Honeywell Experion, Schneider Triconex and Foxboro, Yokogawa CENTUM.
The entries a water plant would recognize are few: two Emerson Ovation controllers, the Schneider SCADAPack 470 and 474 remote terminal unit (certified in 2025), two Honeywell ControlEdge RTU releases, and the Cisco switches that Rockwell sells as Stratix 5200 and 5800.
No meter, analyzer, pump controller, cellular gateway, or small system SCADA package in the index is on the list.
A utility cannot yet buy its way to assurance. For most of the water stack there is no certified option to specify in a tender.
ISASecure is one of several certification schemes; some vendors certify through other bodies, so this understates certification overall. List read November 16, 2026.
Count of certified components and systems per vendor. The other 227 vendors in the index have none.
A Shodan search on November 17, 2026 for the products in this index. Counts cover every sector, not water alone, and include honeypots, so read them as the size of the exposed population a water device sits in.
The controllers named in the July alert are still there. 1,212 MicroLogix 1400 controllers answer on EtherNet/IP, 791 of them in the United States, nearly four months after the federal alert.
Remote screens with no password. 7,112 VNC servers report authentication disabled; 4,796 are in the United States. This is the access path named in sector guidance on hacktivist intrusions.
Some say what they are. 281 exposed pages carry "water treatment" in the title, 179 "wastewater", and 32 "pump station". Most are in the United States.
The Unitronics cleanup held in the United States. 303 devices still identify as Unitronics on the PCOM port; 11 are in the United States.
Cellular gateways are the largest exposed group by far. Sierra Wireless, Cradlepoint, and Teltonika devices are the front door to the controllers behind them.
Hosts matching each product fingerprint, worldwide and in the United States. Shodan, November 17, 2026.
| Product | Layer | World | United States |
|---|
Every radio sold in the United States needs an FCC grant, so the FCC database is a product list for meters, telemetry radios, and cellular modems. Itron has 2,305 grants on record, Sensus 831, Landis+Gyr 256, Aclara 123, Neptune 96, Mueller Systems 91, Badger Meter 82, Kamstrup 51.
Searching device descriptions for water meter terms returns 84 manufacturers. Eleven were added to the index, among them Aclara, Landis+Gyr, ST Engineering Telematics Wireless, and the radio makers FreeWave, XetaWave, and CalAmp. None of the eleven has a water tagged advisory.
NSF lists 2,103 companies certified to its drinking water component standard. Most make pipe, coatings, and filter media. About 30 vendors in the index are on it, and 20 more are now added because they make equipment with electronics: meters (Arad, Metron-Farnier, B Meters), dosing pumps (Blue-White, Milton Roy, SEKO), instruments (Georg Fischer, Burkert, WIKA), disinfection systems (De Nora, Atlantium), and pumps and actuators (Flowserve, Wilo, Gorman-Rupp, Bray).
The listing certifies that materials are safe in contact with drinking water. It says nothing about security, and none of the 20 has a CISA advisory tagged to water.
The quarterly reports through September 2026 record at least eight acquisitions by listed water vendors this year. Four move a sensor or monitoring specialist inside a large group: In-Situ into Veralto, TriOS into Xylem, UDlive into Badger Meter, and Locusview into Itron.
Demand is uneven. Badger Meter sales are down 5.1 percent over nine months on what it calls uneven AMI project pacing, while its software revenue rises. Mueller reports its metering and leak detection segment up 11.4 percent. Veralto reports Water Quality sales up about 10 percent. Energy Recovery revenue is down by half as large desalination projects slipped.
A search of 2026 current reports found no cybersecurity incident disclosure by a water utility or water vendor. The search matches exact phrases, so it can miss filings worded differently.
When a product changes owner, so does the team that issues its security advisories. A utility that tracks vendors by name needs to track who owns them.
Quarterly reports for periods ending June to October 2026, read November 17, 2026. Prices are as stated in the filings.
From quarterly reports of nine listed vendors.
| Buyer | Target | What it makes | When | Price |
|---|---|---|---|---|
| Itron | Locusview | Utility construction software | January | Not stated |
| Veralto | In-Situ | Water monitoring instruments | January | $426M |
| Badger Meter | UDlive | Sewer line monitoring | May | $94M |
| Xylem | TriOS | Optical water quality sensors | July | $219M |
| Xylem | WaterFleet | Mobile water and wastewater services | September | $217M |
| Franklin Electric | Cat Pumps | High pressure pumps | September | $351M |
| Pentair | Taco | Hydronic and water products | October | $1,425M |
| Xylem | Cornell Pump and Roper Pump | Pumps | Agreed August; not closed | $1,460M |
CERT@VDE publishes advisories for 41 manufacturers. Eight were already in the index, among them Endress+Hauser, VEGA, WAGO, and Phoenix Contact. Eight more are now added because they make equipment found in water plants: AUMA valve actuators, Festo process valves, JUMO and ifm sensors, and remote access or cellular routers from MB connect line, Helmholz, Welotec, and ads-tec.
Only part of this reaches CISA. Of the eight added, six have no CISA advisory at all. A utility that watches only the CISA feed does not see their disclosures.
Thirteen annual reports for fiscal 2025 were read. Badger Meter states that about 40 percent of water meters installed in the United States have been converted to AMI; utility water is about 89 percent of its sales. Xylem reports 1.7 billion dollars of smart metering revenue. Hach reports over 149,000 customers. Itron gives no water figure at all.
Four vendors were added from the reports: Franklin Electric, Pentair, Energy Recovery, and the distributor Core & Main, whose catalog shapes which brands reach small utilities. Metering is concentrated: Badger Meter names Sensus, Neptune, Itron, Aclara, Mueller, and Kamstrup as its competitors, and three of those sit inside larger listed groups.
R17 · AI
The Securin AI Discovered CVE Tracker lists 2,740 published CVEs credited to 34 AI discovery systems. For 385 of them a public source says an AI system found the flaw. Seven of those 385 already appear in CISA industrial advisories, and one of those advisories is tagged to water.
Four of the seven are memory safety weaknesses: out of bounds read, integer overflow, double free. All seven arrive through shared components: SQLite, curl, libexpat, libssh2, the Linux kernel, and an OPC UA stack. Five surface in Siemens products. None of the seven is on the CISA exploited list.
A wider group is left out of that count. Another 26 CVEs in industrial advisories are credited to staff of an AI lab or AI security firm, with no public statement that AI was used. Four of those are on the CISA exploited list: two in PHP, one in Brotli, and one in Apache ActiveMQ.
AI systems are finding flaws in the layer utilities cannot see. Among the 385, the tracker holds 12 wolfSSL, 12 FreeRDP, 9 Windows TCP/IP, and 5 Linux kernel CVEs, code that sits under water control systems.
In January 2026 an intruder using commercial AI coding tools built a 17,000 line reconnaissance framework, mapped a Monterrey, Mexico water and drainage utility, and password sprayed its SCADA interface. The attempts failed.
In August 2026 five federal agencies described the same pattern against Siemens S7 controllers: AI generated scripts, built on a public S7 library and disguised as monitoring tools, used to read and write controller memory and logic. The advisory says AI lowers the expertise and time an attack needs. It lists water among the most targeted sectors.
The median time from disclosure to exploitation for water sector flaws is 11 days. AI shortens the attacker side of that window.
Securin AI Discovered CVE Tracker (November 23, 2026) joined to CISA advisories. Only CVEs where a public source says an AI system found the flaw.
| CVE | CWE | Component | Found by | Surfaces in |
|---|
R18 · Water types
Core controllers and SCADA are shared across all six. The differences sit at the edges. This mapping is analyst judgment, not vendor disclosed data.
A treatment plant plus wells, towers, and booster stations on cellular or radio telemetry, and a meter at every customer. Braham, Minnesota lost its well and plant controls for about two hours; Plymouth disconnected two towers.
Least visible: meters and online analyzers. One of 19 metering vendors has a CISA advisory of its own.
Lift stations are the most numerous remote assets and the most likely to sit on a cellular modem. Plymouth disconnected 14 of them; South Dakota reported one affected.
Least visible: packaged digestion and membrane equipment with embedded controllers.
Long conveyance with RTUs over radio and DNP3, few staff, wide geography. 616 DNP3 endpoints were visible in a 2026 scan across sectors, often on carrier networks in small towns.
Least visible: legacy RTUs and radios with no advisory history.
Membrane trains delivered as packaged plants, with distributed control systems at large sites. No federal alert or incident report names a desalination control product.
Least visible: the skid bill of materials and the vendor remote service link.
UV and advanced oxidation skids with dense online monitoring for permit compliance. No public incident record.
Least visible: analyzer and skid controllers that compliance depends on.
Owner operated inside plants and campuses, on the same controller families as municipal systems. Advisories for those controllers are usually tagged to manufacturing.
Least visible: the whole segment. It falls outside municipal reporting.
R19 · Vendor index
Advisory counts come from the full CISA industrial advisory set (4,014 advisories) joined to the exploited catalog (1,792 entries). Vendors outside that set are listed on sector presence, Securin platform data, or other public records (NSF, FCC, CERT@VDE, annual reports), and marked.
| Why it is here |
|---|
R20 · Incident record
R21 · For utilities
Include the ones an integrator or equipment vendor installed. Seven in ten exposed Rockwell controllers in the United States sit on a mobile carrier network (Forescout).
Route remote access through a gateway with multifactor authentication, set passwords, allowlist addresses, and keep a clean offline copy of controller logic.
The water sector tag misses the products that were attacked. Build the watch list from the vendor index: controllers, modems, and enterprise applications.
Request a software bill of materials from skid, meter, and analyzer vendors. Fourteen of 17 exploited flaws were in components.
New vendors, newly exploited flaws, and changes in exposure, as Securin research finds them.
R22 · Securin research
This index extends three earlier Securin studies. They measure the sector by vulnerabilities and attacks; this page adds the vendor and component view.
75 attacks on water in 2024. Vulnerability and misconfiguration exploits led initial access at 27.5 percent; public facing applications 15 percent; compromised credentials 10 percent.
1,807 sector vulnerabilities: 222 weaponized, 43 exploited in the wild, 24 on the CISA exploited list, 10 tied to state actors, 6 to ransomware.
The count rises to 1,935, with 242 public exploits and 43 seen in active attacks. Median time from disclosure to exploitation: 11 days. The live platform count on November 23, 2026 is 2,015, with 260 and 46.
Method and sources